Pump Doesn't Start   

 

Check Power Supply & Fuse

230v VAC power supply. 5 Amp fuse. Motor thermal cut out will reset within 1 to 2 hours.

Inadequate Water Supply

Ensure the full bore isolation valves turned to open position, and that the static head requirements for the pump are met.

Blocked Filters

Clean filters, for location see diagram.

Outlet Position

For activation, outlet hose pipes must point straight up.

Flow Rate from Head

Test flow rate with a weir gauge, flow cup or household measuring jug - 1 lpm.

Negative Head Situation Present

See diagram for recommended positions for positive and negative (universal) shower pumps.

 

 

Pump Doesn't Start   

 

Check Power Supply & Fuse

230v VAC power supply. 5 Amp fuse. Motor thermal cut out will reset within 1 to 2 hours.

Inadequate Water Supply

Ensure the full bore isolation valves turned to open position, and that the static head requirements for the pump are met.

Blocked Filters

Clean filters, for location see diagram.

Outlet Position

For activation, outlet hose pipes must point straight up.

Flow Rate from Head

Test flow rate with a weir gauge, flow cup or household measuring jug - 1 lpm.

Negative Head Situation Present

See diagram for recommended positions for positive and negative (universal) shower pumps.

 

Pump Doesn't Start   

 

Check Power Supply & Fuse

230v VAC power supply. 5 Amp fuse. Motor thermal cut out will reset within 1 to 2 hours.

Inadequate Water Supply

Ensure the full bore isolation valves turned to open position, and that the static head requirements for the pump are met.

Blocked Filters

Clean filters, for location see diagram.

Outlet Position

For activation, outlet hose pipes must point straight up.

Flow Rate from Head

Test flow rate with a weir gauge, flow cup or household measuring jug - 1 lpm.

Negative Head Situation Present

See diagram for recommended positions for positive and negative (universal) shower pumps.

 

 

 



Poor Flow Rate   

 

Blocked Filters

Clean filters, for location see diagram.

Is the Outlet Clear?

Check shower head for scale build up and debris.

Is the Shower Hose Twisted?

Remove head and hose and test.

Negative Head Situation Present

See diagram for recommended positions for positive and negative (universal) shower pumps.

 

 

 

 

Pump Doesn't Start   

 

Blocked Filters

Clean filters, for location see diagram.

Is the Outlet Clear?

Check shower head for scale build up and debris.

Is the Shower Hose Twisted?

Remove head and hose and test.

Negative Head Situation Present

See diagram for recommended positions for positive and negative (universal) shower pumps.

 

Pump Doesn't Start   

 

Blocked Filters

Clean filters, for location see diagram.

Is the Outlet Clear?

Check shower head for scale build up and debris.

Is the Shower Hose Twisted?

Remove head and hose and test.

Negative Head Situation Present

See diagram for recommended positions for positive and negative (universal) shower pumps.

 

 

 

 

 

 

 

 

Pump Runs On   

 

Is an Outlet Open?

Close all outlets attached to the pump.

Water Leak on System

Check system for leaks, e.g. dripping taps, leaking pipes and joints, etc.

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Float Stuck or Faulty

See diagram to unstick the float. If you suspect the float is faulty, please contact our technical team on 01793 820142.

 

 

Pump Runs On   

 

Is an Outlet Open?

Close all outlets attached to the pump.

Water Leak on System

Check system for leaks, e.g. dripping taps, leaking pipes and joints, etc.

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Float Stuck or Faulty

See diagram to unstick the float. If you suspect the float is faulty, please contact our technical team on 01793 820142.

 

Pump Runs On   

 

Is an Outlet Open?

Close all outlets attached to the pump.

Water Leak on System

Check system for leaks, e.g. dripping taps, leaking pipes and joints, etc.

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Float Stuck or Faulty

See diagram to unstick the float. If you suspect the float is faulty, please contact our technical team on 01793 820142.

 

 

 



Pump Pulses   

 

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Flange Not Used

Prevent air getting into the system by using a flange, see diagram.

Water Movement in System

Fit non-return valve as per diagram.

 

 

Pump Pulses   

 

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Flange Not Used

Prevent air getting into the system by using a flange, see diagram.

Water Movement in System

Fit non-return valve as per diagram.

 

Pump Pulses   

 

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Flange Not Used

Prevent air getting into the system by using a flange, see diagram.

Water Movement in System

Fit non-return valve as per diagram.

 

 

 

 

 



 

Temperature Fluctuation   

 

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Flange Not Used

Prevent air getting into the system by using a flange, see diagram.

Water Temperature Too High

The temperature at the pump must not exceed 60ºC.

Blocked Filters

Clean filters, for location see diagram.

 

 

 

 

 

Temperature Fluctuation   

 

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Flange Not Used

Prevent air getting into the system by using a flange, see diagram.

Water Temperature Too High

The temperature at the pump must not exceed 60ºC.

Blocked Filters

Clean filters, for location see diagram.

 

Temperature Fluctuation   

 

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Flange Not Used

Prevent air getting into the system by using a flange, see diagram.

Water Temperature Too High

The temperature at the pump must not exceed 60ºC.

Blocked Filters

Clean filters, for location see diagram.

 

 

Hose Connection Leaking   

 

Is the Pushfit Hose Connection Loose?

If using plastic pipe ensure insert sleeves are used. See diagram.

Is the Thread Hose Connection Loose?

Check washers are in position and thread connections are secure (do not over tighten and do not use thread tape).

 

 

Hose Connection Leaking   

 

Is the Pushfit Hose Connection Loose?

If using plastic pipe ensure insert sleeves are used. See diagram.

Is the Thread Hose Connection Loose?

Check washers are in position and thread connections are secure (do not over tighten and do not use thread tape).

 

Hose Connection Leaking   

 

Is the Pushfit Hose Connection Loose?

If using plastic pipe ensure insert sleeves are used. See diagram.

Is the Thread Hose Connection Loose?

Check washers are in position and thread connections are secure (do not over tighten and do not use thread tape).

 

 

 


 

Noisy Pump   

 

Vibrating Through Mounts

Install on a concrete slab cut to size.

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Water Temperature Too High

The temperature at the pump must not exceed 60ºC.

Blocked Filters

Clean filters, for location see diagram.

Debris Inside Impeller Housing

Back flush pump with water.

 

 

 

 

 

Noisy Pump   

 

Vibrating Through Mounts

Install on a concrete slab cut to size.

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Water Temperature Too High

The temperature at the pump must not exceed 60ºC.

Blocked Filters

Clean filters, for location see diagram.

Debris Inside Impeller Housing

Back flush pump with water.

 

Noisy Pump   

 

Vibrating Through Mounts

Install on a concrete slab cut to size.

Air Trapped in System

Complete an air test - follow our step by step instructions, linked here : Air In System and How To Fix.

Water Temperature Too High

The temperature at the pump must not exceed 60ºC.

Blocked Filters

Clean filters, for location see diagram.

Debris Inside Impeller Housing

Back flush pump with water.

 

 

 

 



 
telephone

01793 820142

Monday - Friday, 9am - 5pm

 

 



 
fast identification

email a photo

ID for direct or nearest match. 

 

 







about us 

Pump World's philosophy is to provide quality pump solutions that are energy saving and low on noise without compromising on performance. 

The Pump World team are here to help you put together the right boosting equipment to optimise your system. Our sister company, Smart Showers, sources the finest Italian shower design for a luxury bathroom experience.

Together, Pump World and Smart Showers provide an all-encompassing system solution - designed to suit you.

Pump World   A limited company, registered in England.
Company Number : 02433506.  Registered At : Unit 11 Woodside Road, Swindon, SN3 4WA.

 

subscribe 


payment methods

           
 
+

Contact

  01793 820142
  Mon - Fri, 9am - 5pm

  Unit 11 Woodside Road, South Marston Industrial Estate, Swindon, Wiltshire, SN3 4WA

Connect on Social


                               

Useful Links

Copyright © 2024 Pump World

Text/HTML