Air can build up in a pump installation over time and when not used regularly. It can cause a variety of issues that are often blamed on the pump. However, a simple air test can clear out your installation and solve the issue - at no extra cost!

  • pump pulsing
  • pump running on
  • excessive noise
  • temperature fluctuation

If your installation is suffering with any of the above, it would be worth running the air test to eliminate air as a fault cause.

Need more information?



 
telephone

01793 820142

Monday - Friday, 9am - 5pm

 

 



 
fast identification

email a photo

ID for direct or nearest match. 

 

 

Complete an air test!

Follow these instructions to remove air from your pump installation.

1. Turn off pump.

2. Remove shower head from hose.

3. Let hose hang into bath or shower tray.

4. Turn the temperature to full cold.

5. Turn the shower on and run for 5 minutes.

6. Turn the temperature to full hot and run for a further 5 minutes.

7. Turn off the shower.

8. Wait at least 20 minutes.

9. Re-power the pump and turn on the shower to test.


A one time or repeated air test could solve your pump installation woes. Or you could try our Installation Fault Finder for other targeted solutions.

Do you have an uncontrolled heat source? This may cause air build up in your pipework.
Please browse our temperature control range below.

Temperature Control (NBS_ProductView)

Logicpress Set
On Sale!

Logicpress Set

Sale : £205.20 £174.00
Pressure / Flow Switch with Gauge

• Controls and Protects the Pump
• Set the Cut-In Pressure Value
• With Automatic Restart and Anti-Jam Feature
£205.20£174.00

Description

 

Logicpress Set : electronic pressure switch control.

Application : Pump management system.

The Logic range is a series of electronic pressure switches that will control and protect an electric pump. They start the pump immediately when a valve in the pipe system is opened and stop the pump immediately when the valve is closed. They maintain a constant system pressure, protect the pump from dry running and reduce the effects of water hammer. They are fitted with non-return valves and have a simple user interface for system status and reset.

Automatic Reset Function : Pump protection from dry running but with automatic reset, enabling the pump to operate normally again during a condition where the lack of water may have been only temporary. These devices are designed to make 10 attempts to start over a 24 hour period. On the 10th attempt, if the condition still exists, ie. it is not temporary, it switches off. A system inspection and manual reset is then required.

Daily Pump Test Function : If for any reason the pump remains idle for 24 consecutive hours, the devices are designed to start up the pump for about 5 seconds. This helps to avoid various problems associated with pumps inactive for long periods.

These units must be operated vertically. The column of water between the switch and the highest outlet must not exceed 15 metres (1.5 Bar) - the ‘restart pressure value setting’ - otherwise the system pressure may not fall to the pre-set ‘cut-in’ pressure and the system will not restart. The Logicpress Set has three pre-programmed restart pressure settings of 1.5, 2.0 and 2.5 Bar which can be programmed by the user to serve a range of duties. Minimum flow required inwards is 1 lpm.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

Specifications

Maximum Pressure
12.0 Bar

Maximum Temperature
65ºC

Connection
1.0" BSPM

 

 

Installation Kit

Logicpress Set
Qty 1

 

 

 

 

 
 

Related Products

Pressure / Flow Switch with Gauge

• Controls and Protects the Pump
• Energise with 115 Vac or 230 Vac
• With Automatic Restart and Anti-Jam Feature

£199.20£151.20

12 Amp Digital Pressure Switch

• Compact, Lightweight Design
• High Accuracy and Screen Resolution
• Replaces Teddington or Sq D Switches

£0.00 exc. VAT

Flow Controller

• Controls and Protects the Pump
• Dry Run Protection
• Maintenance Free

£0.00 exc. VAT

Motor Output 1Ph x 1Ph

• Maintains Constant Pressure
• Independent of Flow
• Compact Design

£0.00 exc. VAT

If the air test does not resolve your issue, a regenerative pump that can handle air may be required.
Please browse our quiet Supergen regenerative range below.

Supergen Brass (NBS_ProductView)

Logicpress Set
On Sale!

Logicpress Set

Sale : £205.20 £174.00
Pressure / Flow Switch with Gauge

• Controls and Protects the Pump
• Set the Cut-In Pressure Value
• With Automatic Restart and Anti-Jam Feature
£205.20£174.00

Description

 

Logicpress Set : electronic pressure switch control.

Application : Pump management system.

The Logic range is a series of electronic pressure switches that will control and protect an electric pump. They start the pump immediately when a valve in the pipe system is opened and stop the pump immediately when the valve is closed. They maintain a constant system pressure, protect the pump from dry running and reduce the effects of water hammer. They are fitted with non-return valves and have a simple user interface for system status and reset.

Automatic Reset Function : Pump protection from dry running but with automatic reset, enabling the pump to operate normally again during a condition where the lack of water may have been only temporary. These devices are designed to make 10 attempts to start over a 24 hour period. On the 10th attempt, if the condition still exists, ie. it is not temporary, it switches off. A system inspection and manual reset is then required.

Daily Pump Test Function : If for any reason the pump remains idle for 24 consecutive hours, the devices are designed to start up the pump for about 5 seconds. This helps to avoid various problems associated with pumps inactive for long periods.

These units must be operated vertically. The column of water between the switch and the highest outlet must not exceed 15 metres (1.5 Bar) - the ‘restart pressure value setting’ - otherwise the system pressure may not fall to the pre-set ‘cut-in’ pressure and the system will not restart. The Logicpress Set has three pre-programmed restart pressure settings of 1.5, 2.0 and 2.5 Bar which can be programmed by the user to serve a range of duties. Minimum flow required inwards is 1 lpm.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

Specifications

Maximum Pressure
12.0 Bar

Maximum Temperature
65ºC

Connection
1.0" BSPM

 

 

Installation Kit

Logicpress Set
Qty 1

 

 

 

 

 
 

Related Products

Pressure / Flow Switch with Gauge

• Controls and Protects the Pump
• Energise with 115 Vac or 230 Vac
• With Automatic Restart and Anti-Jam Feature

£199.20£151.20

12 Amp Digital Pressure Switch

• Compact, Lightweight Design
• High Accuracy and Screen Resolution
• Replaces Teddington or Sq D Switches

£0.00 exc. VAT

Flow Controller

• Controls and Protects the Pump
• Dry Run Protection
• Maintenance Free

£0.00 exc. VAT

Motor Output 1Ph x 1Ph

• Maintains Constant Pressure
• Independent of Flow
• Compact Design

£0.00 exc. VAT






about us 

Pump World's philosophy is to provide quality pump solutions that are energy saving and low on noise without compromising on performance. 

The Pump World team are here to help you put together the right boosting equipment to optimise your system. Our sister company, Smart Showers, sources the finest Italian shower design for a luxury bathroom experience.

Together, Pump World and Smart Showers provide an all-encompassing system solution - designed to suit you.

Pump World   A limited company, registered in England. VAT No: GB535638919.
Company Number : 02433506.  Registered At : Unit 11 Woodside Road, Swindon, SN3 4WA.

 

payment methods

           

Text/HTML