Thermostatic Blending Valve : non-failsafe valve for general use.

Application : Designed to maintain the preset temperature of the mixed water delivered to the user despite variations in the temperature of the water contained in the system.

This range is suitable for electric cylinders or cylinders heated by oil or gas. Ideal for use on underfloor heating to maintain the circulating water through the underfloor coil at the preset temperature, by mixing hot water from the boiler with the return water from the coil. Must not be used in combination with boilers with instantaneous hot water production for sanitary purposes. Adding them would impair the operation of the boiler.

Supplied with parallel threaded ends complying with BS EN ISO 228-1.

Operating Principle : the regulating element within the thermostatic mixing valve consists of a temperature sensor in contact with the mixed water outlet. By expanding and contracting the sensor continuously ensures correct proportioning of the incoming hot and cold water by modulating with the obturator on the incoming cold water.

Check valves should be installed in systems with thermostatic mixing valves to prevent undesired backflows. The thermostatic mixing valve must be commissioned in accordance with current regulations and by a qualified engineer using suitable temperature measuring equipment. We recommend the use of a digital thermometer for measuring the temperature of the mixed water.

The control knob is used to adjust the temperature from 40˚C to 60˚C.

To ensure suitability for your application, please call our technical team on 01793 820142.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

 

Specifications

Maximum Pressure
10.0 Bar Static
5.0 Bar Dynamic

Setting Range
40°C to 60°C

Minimum Flow Rate
5 lpm

Dimensions
W x H (mm)
64 x 103

 

 

Installation Kit

Thermostatic Blending Valve 1.0"
Qty 1

 

 

 

 

 
 

Related Products

Suitable for agas, raeburns or solar heat source.

• 1.0" Connection
• 90˚C Max Inlet Temperature
• Certified by the DTC Scheme

£342.00£290.40
Thermostatic Blending Valve
On Sale!

Temp Blending Valve

Sale : £355.20 £302.40
Suitable for electric cylinders or cylinders heated by oil or gas, and underfloor heating.

• 1.0" Connection
• 40˚C to 60˚C Setting Range
• Parallel Threaded Ends
£355.20£302.40

Description

 

Thermostatic Blending Valve : non-failsafe valve for general use.

Application : Designed to maintain the preset temperature of the mixed water delivered to the user despite variations in the temperature of the water contained in the system.

This range is suitable for electric cylinders or cylinders heated by oil or gas. Ideal for use on underfloor heating to maintain the circulating water through the underfloor coil at the preset temperature, by mixing hot water from the boiler with the return water from the coil. Must not be used in combination with boilers with instantaneous hot water production for sanitary purposes. Adding them would impair the operation of the boiler.

Supplied with parallel threaded ends complying with BS EN ISO 228-1.

Operating Principle : the regulating element within the thermostatic mixing valve consists of a temperature sensor in contact with the mixed water outlet. By expanding and contracting the sensor continuously ensures correct proportioning of the incoming hot and cold water by modulating with the obturator on the incoming cold water.

Check valves should be installed in systems with thermostatic mixing valves to prevent undesired backflows. The thermostatic mixing valve must be commissioned in accordance with current regulations and by a qualified engineer using suitable temperature measuring equipment. We recommend the use of a digital thermometer for measuring the temperature of the mixed water.

The control knob is used to adjust the temperature from 40˚C to 60˚C.

To ensure suitability for your application, please call our technical team on 01793 820142.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

 

Specifications

Maximum Pressure
10.0 Bar Static
5.0 Bar Dynamic

Setting Range
40°C to 60°C

Minimum Flow Rate
5 lpm

Dimensions
W x H (mm)
64 x 103

 

 

Installation Kit

Thermostatic Blending Valve 1.0"
Qty 1

 

 

 

 

 
 

Related Products

Suitable for agas, raeburns or solar heat source.

• 1.0" Connection
• 90˚C Max Inlet Temperature
• Certified by the DTC Scheme

£342.00£290.40
Thermostatic Blending Valve
On Sale!

Temp Blending Valve

Sale : £355.20 £302.40
Suitable for electric cylinders or cylinders heated by oil or gas, and underfloor heating.

• 1.0" Connection
• 40˚C to 60˚C Setting Range
• Parallel Threaded Ends
£355.20£302.40

Description

 

Thermostatic Blending Valve : non-failsafe valve for general use.

Application : Designed to maintain the preset temperature of the mixed water delivered to the user despite variations in the temperature of the water contained in the system.

This range is suitable for electric cylinders or cylinders heated by oil or gas. Ideal for use on underfloor heating to maintain the circulating water through the underfloor coil at the preset temperature, by mixing hot water from the boiler with the return water from the coil. Must not be used in combination with boilers with instantaneous hot water production for sanitary purposes. Adding them would impair the operation of the boiler.

Supplied with parallel threaded ends complying with BS EN ISO 228-1.

Operating Principle : the regulating element within the thermostatic mixing valve consists of a temperature sensor in contact with the mixed water outlet. By expanding and contracting the sensor continuously ensures correct proportioning of the incoming hot and cold water by modulating with the obturator on the incoming cold water.

Check valves should be installed in systems with thermostatic mixing valves to prevent undesired backflows. The thermostatic mixing valve must be commissioned in accordance with current regulations and by a qualified engineer using suitable temperature measuring equipment. We recommend the use of a digital thermometer for measuring the temperature of the mixed water.

The control knob is used to adjust the temperature from 40˚C to 60˚C.

To ensure suitability for your application, please call our technical team on 01793 820142.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

 

Specifications

Maximum Pressure
10.0 Bar Static
5.0 Bar Dynamic

Setting Range
40°C to 60°C

Minimum Flow Rate
5 lpm

Dimensions
W x H (mm)
64 x 103

 

 

Installation Kit

Thermostatic Blending Valve 1.0"
Qty 1

 

 

 

 

 
 

Related Products

Suitable for agas, raeburns or solar heat source.

• 1.0" Connection
• 90˚C Max Inlet Temperature
• Certified by the DTC Scheme

£342.00£290.40

NBS_ProductView

Thermostatic Blending Valve
On Sale!

Temp Blending Valve

Sale : £355.20 £302.40
Suitable for electric cylinders or cylinders heated by oil or gas, and underfloor heating.

• 1.0" Connection
• 40˚C to 60˚C Setting Range
• Parallel Threaded Ends
£355.20£302.40

Description

 

Thermostatic Blending Valve : non-failsafe valve for general use.

Application : Designed to maintain the preset temperature of the mixed water delivered to the user despite variations in the temperature of the water contained in the system.

This range is suitable for electric cylinders or cylinders heated by oil or gas. Ideal for use on underfloor heating to maintain the circulating water through the underfloor coil at the preset temperature, by mixing hot water from the boiler with the return water from the coil. Must not be used in combination with boilers with instantaneous hot water production for sanitary purposes. Adding them would impair the operation of the boiler.

Supplied with parallel threaded ends complying with BS EN ISO 228-1.

Operating Principle : the regulating element within the thermostatic mixing valve consists of a temperature sensor in contact with the mixed water outlet. By expanding and contracting the sensor continuously ensures correct proportioning of the incoming hot and cold water by modulating with the obturator on the incoming cold water.

Check valves should be installed in systems with thermostatic mixing valves to prevent undesired backflows. The thermostatic mixing valve must be commissioned in accordance with current regulations and by a qualified engineer using suitable temperature measuring equipment. We recommend the use of a digital thermometer for measuring the temperature of the mixed water.

The control knob is used to adjust the temperature from 40˚C to 60˚C.

To ensure suitability for your application, please call our technical team on 01793 820142.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

 

Specifications

Maximum Pressure
10.0 Bar Static
5.0 Bar Dynamic

Setting Range
40°C to 60°C

Minimum Flow Rate
5 lpm

Dimensions
W x H (mm)
64 x 103

 

 

Installation Kit

Thermostatic Blending Valve 1.0"
Qty 1

 

 

 

 

 
 

Related Products

Suitable for agas, raeburns or solar heat source.

• 1.0" Connection
• 90˚C Max Inlet Temperature
• Certified by the DTC Scheme

£342.00£290.40
Thermostatic Blending Valve
On Sale!

Temp Blending Valve

Sale : £355.20 £302.40
Suitable for electric cylinders or cylinders heated by oil or gas, and underfloor heating.

• 1.0" Connection
• 40˚C to 60˚C Setting Range
• Parallel Threaded Ends
£355.20£302.40

Description

 

Thermostatic Blending Valve : non-failsafe valve for general use.

Application : Designed to maintain the preset temperature of the mixed water delivered to the user despite variations in the temperature of the water contained in the system.

This range is suitable for electric cylinders or cylinders heated by oil or gas. Ideal for use on underfloor heating to maintain the circulating water through the underfloor coil at the preset temperature, by mixing hot water from the boiler with the return water from the coil. Must not be used in combination with boilers with instantaneous hot water production for sanitary purposes. Adding them would impair the operation of the boiler.

Supplied with parallel threaded ends complying with BS EN ISO 228-1.

Operating Principle : the regulating element within the thermostatic mixing valve consists of a temperature sensor in contact with the mixed water outlet. By expanding and contracting the sensor continuously ensures correct proportioning of the incoming hot and cold water by modulating with the obturator on the incoming cold water.

Check valves should be installed in systems with thermostatic mixing valves to prevent undesired backflows. The thermostatic mixing valve must be commissioned in accordance with current regulations and by a qualified engineer using suitable temperature measuring equipment. We recommend the use of a digital thermometer for measuring the temperature of the mixed water.

The control knob is used to adjust the temperature from 40˚C to 60˚C.

To ensure suitability for your application, please call our technical team on 01793 820142.

 

 

Useful Downloads

 View Data Sheet
  product specification, available for download

 

 

 

 

 

Specifications

Maximum Pressure
10.0 Bar Static
5.0 Bar Dynamic

Setting Range
40°C to 60°C

Minimum Flow Rate
5 lpm

Dimensions
W x H (mm)
64 x 103

 

 

Installation Kit

Thermostatic Blending Valve 1.0"
Qty 1

 

 

 

 

 
 

Related Products

Suitable for agas, raeburns or solar heat source.

• 1.0" Connection
• 90˚C Max Inlet Temperature
• Certified by the DTC Scheme

£342.00£290.40


 
telephone

01793 820142

Monday - Friday, 9am - 5pm

 

 



 
fast identification

email a photo

ID for direct or nearest match. 

 

 

Which waste water set is right for my application?

When it comes to enquiries on waste water removal, the Pump World technical team will ask three main questions - what are you pumping, what distance are you pumping and what do you need the system to do? This will help you narrow down your choice and with our specification service we can provide the right system for your application.

For product advice or recommendations, call or email our team today.

 

 







about us 

Pump World's philosophy is to provide quality pump solutions that are energy saving and low on noise without compromising on performance. 

The Pump World team are here to help you put together the right boosting equipment to optimise your system. Our sister company, Smart Showers, sources the finest Italian shower design for a luxury bathroom experience.

Together, Pump World and Smart Showers provide an all-encompassing system solution - designed to suit you.

Pump World   A limited company, registered in England. VAT No: GB535638919.
Company Number : 02433506.  Registered At : Unit 11 Woodside Road, Swindon, SN3 4WA.

 

payment methods

           

Text/HTML